﻿1
00:00:03,770 --> 00:00:04,371
>> THE PYROTECHNICS

2
00:00:04,371 --> 00:00:05,805
TEST FACILITY SUPPORTS

3
00:00:05,805 --> 00:00:07,507
TESTING OF PYROTECHNICALLY

4
00:00:07,507 --> 00:00:08,875
ACTUATED DEVICES

5
00:00:08,875 --> 00:00:10,577
AND INCLUDES THE CAPABILITY

6
00:00:10,577 --> 00:00:11,811
TO SUBJECT HARDWARE

7
00:00:11,811 --> 00:00:12,612
TO VIBRATION

8
00:00:12,612 --> 00:00:14,280
AND PYROSHOCK ENVIRONMENTS

9
00:00:14,280 --> 00:00:15,115
ENCOUNTERED DURING

10
00:00:15,115 --> 00:00:16,649
LAUNCHES AND LANDINGS.

11
00:00:16,649 --> 00:00:17,884
THE FACILITY INCLUDES

12
00:00:17,884 --> 00:00:19,119
AN EXPLOSIVE LOADING

13
00:00:19,119 --> 00:00:20,320
AND HANDLING AREA

14
00:00:20,320 --> 00:00:21,721
AND PYROTECHNIC STORAGE

15
00:00:21,721 --> 00:00:23,523
IN EARTH-COVERED BUNKERS.

16
00:00:23,523 --> 00:00:24,958
WITH THE UNIQUE CAPABILITY

17
00:00:24,958 --> 00:00:26,426
TO PERFORM NASA-STANDARD

18
00:00:26,426 --> 00:00:27,827
INITIATOR TESTING

19
00:00:27,827 --> 00:00:30,263
IN -420 DEGREES FAHRENHEIT,

20
00:00:30,263 --> 00:00:31,931
THE FACILITY IS RESPONSIBLE

21
00:00:31,931 --> 00:00:33,967
FOR LOT-TESTING ALL SPACECRAFT

22
00:00:33,967 --> 00:00:35,769
APPLICATIONS FOR NASA.

23
00:00:35,769 --> 00:00:37,070
SOPHISTICATED EQUIPMENT

24
00:00:37,070 --> 00:00:38,505
FOR MEASURING SPEEDS OF UP TO

25
00:00:38,505 --> 00:00:40,006
10,000 METERS PER SECOND

26
00:00:40,006 --> 00:00:41,040
IS AVAILABLE.

27
00:00:42,842 --> 00:00:52,919
[ MUSIC ]

28
00:00:52,919 --> 00:00:54,354
THE VIBRATION SHAKER SYSTEM

29
00:00:54,354 --> 00:00:55,688
IS CAPABLE OF SUBJECTING

30
00:00:55,688 --> 00:00:57,056
COMPONENTS AND SYSTEMS

31
00:00:57,056 --> 00:00:58,758
TO RANDOM AND SINUSOIDAL

32
00:00:58,758 --> 00:01:00,160
VIBRATION LEVELS.

33
00:01:00,160 --> 00:01:01,895
THE VIBRATION TABLE IS LOCATED

34
00:01:01,895 --> 00:01:04,097
IN A BLAST-RESISTANT TEST CELL

35
00:01:04,097 --> 00:01:05,432
CAPABLE OF HANDLING

36
00:01:05,432 --> 00:01:07,066
SMALL AMOUNTS OF PYROTECHNICS

37
00:01:07,066 --> 00:01:08,234
OR OTHER HAZARDOUS

38
00:01:08,234 --> 00:01:09,569
TEST ARTICLES.

39
00:01:09,569 --> 00:01:11,604
THE TEST FACILITY ALSO HOUSES

40
00:01:11,604 --> 00:01:13,907
TWO PYROSHOCK TEST STANDS,

41
00:01:13,907 --> 00:01:16,075
THE TUNABLE-BEAM AIR CANNON

42
00:01:16,075 --> 00:01:18,311
AND THE RESIDENT PLATE STAND.

43
00:01:18,311 --> 00:01:19,612
BOTH OF THESE TEST STANDS

44
00:01:19,612 --> 00:01:20,413
ARE UTILIZED FOR

45
00:01:20,413 --> 00:01:21,581
SUBJECTING COMPONENTS

46
00:01:21,581 --> 00:01:23,149
TO SHOCK ENVIRONMENTS.
